Import CTP rules

If your site already redacts burned-in text with the RSNA Clinical Trial Processor (CTP), its DicomPixelAnonymizer.script holds the pixel regions you trust for each machine. Isocenter can convert that script into rules you then copy into a configuration's machines: list.

Convert the script

python -m isocenter.utils.ctp_parser /path/to/DicomPixelAnonymizer.script ctp_rules.yaml

It prints Successfully converted N rules to ctp_rules.yaml. For a script block such as

GE LOGIQ ultrasound banner
{ Manufacturer.containsIgnoreCase("GE") * ManufacturerModelName.containsIgnoreCase("LOGIQ E9") }
(0,0,640,40)

the output is

rules:
- manufacturer: GE
  model_name: LOGIQ E9
  comment: 'Imported from CTP. Condition: Manufacturer.containsIgnoreCase("GE") *
    ManufacturerModelName.containsIgnoreCase("LOGIQ E9")'
  redaction_zones:
  - - 0
    - 40
    - 0
    - 640

What the converter reads:

  • One rule per block whose condition names a Manufacturer or a ManufacturerModelName with containsIgnoreCase, and which is followed by at least one (x,y,w,h) region. Any other block is skipped, so the count it prints can be lower than the number of blocks in the script. Other conditions in a block (Rows.equals(...), CommentsOnRadiationDose...) are not read; they survive only in the comment.
  • Coordinates are converted. CTP writes (x, y, width, height); Isocenter zones are [row_start, row_end, col_start, col_end] in pixels, so (x,y,w,h) becomes [y, y+h, x, x+w].
  • No serial number. CTP matches a manufacturer and model; Isocenter matches a machine by its Device Serial Number. A block with a manufacturer but no model gets model_name: Unknown.

Use the rules in a configuration

The output is a rule list, not a configuration: load_config() refuses it with ValueError: ...: unknown key 'rules' at the top level. Copy each rule you want into the machines: list of your configuration and add the serial_number of the machine it is for:

machines:
  - serial_number: "US12345"
    manufacturer: GE
    model_name: LOGIQ E9
    comment: 'Imported from CTP.'
    redaction_zones:
    - - 0
      - 40
      - 0
      - 640

Quote the serial number. Give one entry per machine: two scanners of the same model are two entries with the same zones. Then check the zones against your own images before you rely on them: see Pixel Redaction (Machines) and Burned-in text (OCR).

The built-in CTP knowledge base

create_config() already knows the rules from CTP's published script. For each machine in your data it looks for an exact serial number in its own knowledge base first, then for a CTP rule whose manufacturer and model are both contained in the machine's (ignoring case), and writes the zones it finds into the new configuration with a comment naming the source. You need the converter only for a script your site has written or changed.